Home » Articles and guides » RS and RKO rules

RS and RKO rules: practical application

Watchkeeping monitoring: where acknowledgement devices should be placed

When selecting a bridge navigational watch alarm system, identify more than the main-unit location. Acknowledgement and reset devices must be accessible from working positions while located where a proper lookout can be maintained. The number of buttons therefore follows the bridge layout and watchkeeping tasks.

Schematic illustration of a single-button device near a bridge window with an unobstructed sea view, without labels
Original editorial illustration. The layout is schematic; the drawing specifies no installation dimensions and does not depict a particular product version.

The requirement and its scope

The basis is clauses 3.4.7.1–3.4.7.3 of Part V, Navigation Equipment, of the RS Rules for the Equipment of Sea-Going Ships, edition 01.01.2026. Under clause 1.1.1, this Part covers self-propelled ships not engaged on international voyages. Requirements for other operating conditions must be established separately. Under clause 1.1.3, flag State maritime-administration instructions take precedence in the event of conflict.

Clause 3.4.7.1 provides for audible/visual alarm acknowledgement and system-reset devices to be located only at bridge positions where a proper lookout can be maintained. Locations near visual indicators are preferred. They must be readily accessible from the ship-control position, navigation and manoeuvring station, lookout position and bridge wings.

Consider these conditions together. A convenient button at a position without a proper view does not become suitable merely through easy access. Equally, adequate visibility does not remove the need to check access from the required stations.

Who may use the device?

Clause 3.4.7.2 requires a design allowing use only by the officer of the watch present on the bridge and preventing unintended use by other persons. This is a separate issue from positioning the main display.

The design needs details of the actual device and intended acknowledgement method. Check capabilities against documentation for the selected version; an optional sensor does not establish that it may replace every specified acknowledgement function without assessment.

Emergency calling is a separate function

Under clause 3.4.7.3, a dedicated emergency-call button may be installed at the navigation and manoeuvring station. It initiates the second-stage alarm immediately, followed by the third stage, when the backup officer and/or master must be called urgently to the bridge.

The word 'may' must not be turned into an unconditional requirement to fit that button on every vessel. This concerns calling within the watch alarm system, rather than a radio distress alert via DSC. The specification must identify these functions separately.

An actual system for discussing package contents

The manufacturer presents NSR NBW-1000 as a marine BNWAS. Its documentation distinguishes control, distribution, acknowledgement and alarm devices. NAV Marine group catalogue: NSR NBW-1000 BNWAS. This link opens another site in the group.

A standard commercial package does not establish that its device quantities are sufficient for a particular bridge. Package contents, location-specific versions and required documentation must be defined in the specification. A BNWAS name alone establishes neither approval of the particular system nor installation compliance.

Information to include in the enquiry

InformationPurpose
Vessel type, class and operating areaEstablish the applicable framework
Bridge plan showing working positions and wingsCheck access and lookout positions
Intended acknowledgement devicesCheck actual functions and versions
Existing alarm-system configurationEstablish the retained installation scope
Emergency-call requirementAgree this function separately

The quotation should distinguish equipment, placement, installation and testing. The result must concern the vessel's actual working positions, rather than only a working button on the supplier's bench.

Sources: the official Part V of the RS Rules, clauses 1.1.1–1.1.3 and 3.4.7.1–3.4.7.3; the official NSR NBW-1000 page. The drawing is schematic and does not depict a particular device version.

Send project details for a quotation

All guides in this series