RS and RKO rules: practical application
Navigation cables: checks before routing
Route length is only the start of a cable schedule for a new radar. The design must establish each cable type, shielding, deck-connection conditions and allowable bends. Testing the installed cable before connecting equipment is a separate stage. This helps distinguish installation defects from the condition of electronic units.

Where section 3.5 applies
The technical guide is based on clauses 3.5.1–3.5.4 of Part V, Navigation Equipment, of the RS Rules for the Equipment of Sea-Going Ships, edition 01.01.2026. Under clause 1.1.1, this Part concerns self-propelled ships not engaged on international voyages. For other operating conditions, establish the applicable framework separately. Additional flag-administration instructions are taken into account under clause 1.1.3 and applied in the event of conflict with the rules.
Clause 3.5.1 specifies shielding for all external-installation cables of navigation equipment. They must be laid in accordance with the manufacturer's technical documentation, taking account of Part XI, Electrical Equipment, of the Rules for the Classification and Construction of Sea-Going Ships. 'External' must not be replaced with 'open deck only': the clause concerns external installation of equipment aboard the vessel.
Insulation testing requires cable disconnection
Clause 3.5.2 specifies the minimum insulation resistance of an installed cable: 20 MΩ regardless of length. The condition is essential: the cable is disconnected at both ends. This requirement must not be turned into advice to attach a test instrument to a line with electronics still connected.
Safe disconnection, test voltage, whether a particular line may be tested and restoration of connections must follow the documentation and agreed work procedure. Section 3.5 itself provides no universal test setting for every digital interface or connector. Record the result with the tested cable designation and its actual disconnection arrangement.
Deck connection and bending - different checks
Under clause 3.5.3, connections on open deck must prevent moisture ingress and have a rating of IP56. Check the complete actual connection: compatible connector halves, entries, seals and assembly. A marking on one component does not establish the water protection of the assembled connection.
Clause 3.5.4 separately requires compliance with the minimum permissible internal bend radius of cables and microwave transmitting feeders. Route length must therefore allow for actual turns and entries. Use the radius specified for the selected product; these clauses do not establish one value for all cables and waveguides.
Example of application for a replacement radar
KODEN MDC-7912P is an actual marine radar with separate display and controls. Prepare a schedule of the actual connections for the selected package. The radar name alone cannot establish cable interchangeability or permission to retain an existing feeder.
| Background data | What's the point? |
|---|---|
| Model and version of each unit | Connections specified by the manufacturer |
| Cable-route length, turns and entries | Whether length and bend radii are sufficient |
| Open deck sections | Which connections require IP56 |
| Cables to be retained and their markings | Do I need a separate inspection and inspection? |
| Measurement protocols | The line and procedure to which the result relates |
In the request, divide the supply of cables, connecting accessories, gasket and verification. Attach a diagram, photos of the inputs and information about the vessel, class and area of navigation. This will provide the basis for subject quotation and subsequent acceptance.
Sources
Rule: the official Part V of the RS Rules1.1.1 to 1.1.3 and 3.5.1 to 3.5.4. The role of the model: the manufacturer's KODEN MDC-7912P information. The conditional drawing does not show the electrical circuit and does not specify the type of cable.