MG5424: installation clearance, magnetic materials and cooling

When ordering an MG5424, it is important for an existing transmitter to check the installation location, not just the power and range. The factory sheet contains requirements for the built-in magnet environment and mechanical interfacing. They are especially significant if previously changed brackets, body or adjacent parts.

Request a quote

MG5424: Image from RadarStation's own catalog
MG5424 from the RadarStation catalog. Please request photos of marking and condition of the offered copy before ordering.

The gap refers to magnetic materials

The e2v sheet A1A-MG5424, Issue 6 of June 2016, specifies a minimum gap of 25 mm between the magnetron and magnetic materials. This is a specific requirement for the node environment that should not be replaced by a “hull fits” rating. For repair, photos of the regular place and information about the alterations near the magnetron are useful.

If another bracket or additional part is offered, the service should check their effect on compliance with factory conditions. The coincidence of the holes does not answer this question.

Cooling and free volume

In the same edition, cooling is designated as natural. This does not mean that a magnetron can be placed in an arbitrary tight compartment. It is necessary to maintain the heat sink conditions provided for by the design of the transmitter, and take into account changes in the casings or the placement of adjacent components.

In the application, note whether the regular installation is fully maintained. If not, add a description of the modified design: the price of one spare part does not automatically include checking the converted transmitter.

Check the mounting against the drawing

The sheet MG5424 contains a separate overall drawing and indicates the output connector IEC UBR100. For coordination, appropriate transmitter documentation, mounting data and the type of interfaced surfaces are needed. The photo of the product in the catalog does not show the planeness of the landing and the state of the actual connection.

  • Transmitter model and magnetron number on his ZIP.
  • Photo of the installed node and neighboring details.
  • Whether there are changes in mounting, body or cooling.
  • What configuration and what accessories are required to be installed.

What to do after replacement

Coordinate with the service the installation check and the operation of the transmitter in the standard configuration. For another configuration or modified mounting, request the basis of applicability. Available factory sheet helps to formulate questions, but does not replace the documentation of your installation and verification of the proposed instance.

Card and documents

Supply and coordination

MG5424 is present in the warehouse catalogue with a price see product card. Availability, reserve, condition of a particular instance and current price are confirmed before ordering.

Price and term - by quotation for the agreed composition. Specify the port or city, the required date, documents and method of acceptance. A mark in the catalog helps to select a position for the request; the actual balance and reserve are confirmed before the order.

Request a quote