RS and RKO rules: practical application
Heading repeaters: the purpose of each station
When adding a heading repeater, first establish the purpose of the working position. A bearing-taking station, an indicator at the ship-control position and an instrument beside the emergency steering station have different functions. A list of identical repeaters without a layout does not establish which requirements have actually been met.

The requirement and its scope
This guide is based on clauses 3.4.2.3–3.4.2.7 of Part V, Navigation Equipment, of the RS Rules for the Equipment of Sea-Going Ships, edition 01.01.2026. Under clause 1.1.1, this Part covers self-propelled ships not engaged on international voyages. Establish the applicable framework for other cases separately. Under clause 1.1.3, additional flag-administration instructions take precedence in the event of conflict.
Bearing repeaters under clause 3.4.2.3 are arranged so that collectively they permit bearings around the full 360° horizon. This does not require every individual instrument to provide a 360° view. Under clause 3.4.2.4, the steering repeater is installed at the ship-control position.
Under clause 3.4.2.5, a repeater must be immediately adjacent to the emergency steering position where such a position is provided. This siting condition must not become a separate requirement to create a new emergency steering station on every vessel.
Bearing-taking station and reference line
Clause 3.4.2.6 specifies that the 0–180° lines of bearing repeaters lie in or parallel to the fore-and-aft centreline plane, with an accuracy of 0.2°. This is a separate installation check. Correct heading readings on the supplier's bench do not establish correct alignment of the bearing-taking station after installation.
The plan should identify the operating function, observation sector, mounting and reference-line direction. Check actual instrument and accessory versions and documentation: a circular scale alone does not establish the complete equipment required for bearing-taking.
When source indication is required
Clause 3.4.2.7 permits shared repeaters for a gyrocompass and a remotely transmitting magnetic compass. With this arrangement, the repeaters must indicate the heading source. This is a condition of the shared system, rather than a statement that every repeater must receive two sources.
The manufacturer's TG-8000/8500 manual distinguishes step and serial outputs and refers to vessel as-built diagrams. The general word 'heading' is insufficient to establish the interface and compatibility of particular devices.
A catalogue item for discussion
The catalogue includes Tokyo Keiki RP51-1. The historical TG-8000/8500 configuration lists it as a serial-type repeater. This helps identify its family, but does not establish suitability of any unit for any station, current documents, condition or accessories. A historical certificate is not used as evidence of present-day approval.
| Information needed for selection | Purpose |
|---|---|
| Vessel, class and working-position layout | Establish the scope and instrument functions |
| Gyrocompass and output designations | Identify the actual source and signal type |
| Required bearing-taking sectors | Check combined coverage |
| Whether an emergency steering station is provided | Apply the conditional requirement in 3.4.2.5 |
| Shared repeaters and source switching | Check heading-source indication |
The quotation should distinguish the repeater, mounting, accessories, connections and work. After installation, check station functions and positions together with the operating heading-transmission arrangement.
Sources: the official Part V of the RS Rules, clauses 1.1.1–1.1.3 and 3.4.2.3–3.4.2.7; Tokyo Keiki manual E10-1076F, sections 1.3.1–1.3.2; historical system configuration, appendix 1. The drawing does not depict a particular RP51-1.