Thrane & Thrane SAILOR RT5022: BaseBand and C83 / S-328.700

In Thrane & Thrane’s SAILOR RT5022, the BaseBand module is responsible for signal management and processing. When searching for a repair unit, it is useful to distinguish this entire board from the individual component of the C83. In the factory manual, the number S-328.700 appears, but it does not indicate a complete BaseBand PCB.

Request a quote

BaseBand module inside SAILOR RT5022 and a separate component of C83, listed in the service manual as S-328.700
Conditional scheme of product levels according to the documentation of Thrane & Thrane. Not a repair scheme, not a warehouse board photo. A separate board or C83 has not been confirmed.

C83 and S-328.700: What the manufacturer says

Repair Instruction 97-131251, March 2010, is dedicated to the C83 capacitor on the BaseBand PCB radio series VHF5000, including RT5022 and RT5020. S-328.700 is listed as the capacitor order number. It cannot be transferred to the entire management board.

Instructions consider the weakening or absence of the sound of the internal speaker. The manufacturer specifies other possible reasons: the replacement of the C83 does not guarantee the elimination of any sound failure. Therefore, the message “no sound” is useful for starting a diagnosis, but does not yet determine the subject of the purchase.

What exactly to include in the application
DesignationProduct level
RT5022Radio and agreed composition of the recovery
BaseBand PCB / BB moduleInternal board: full labeling and audit required
C83 / S-328.700Component according to instruction 97-131251, separate availability

BaseBand Replacement Requires Adjustment of Settings

Workshop Manual W5022GB, Issue B/1007, Section 3.2.11, indicates that configuration and identification data are located in BaseBand. After replacing the board or the base unit, a service configuration is provided. System settings, such as a serial number, are not included in parameters that are automatically copied back.

Thus, the quotation should be compared according to the full result: the desired hardware assembly, its applicability and the work, after which the station is checked in the agreed configuration. The matching name of the board does not replace the confirmation of its configuration. Transferring someone else’s identity should not be considered a normal copy of user settings.

What to transfer to the service and the supplier

Specify the serial number and full station configuration, the readable marking of the board, the observed failure and the available conclusion of the service. Separately indicate whether you need to restore the proposed warehouse RT5022 or select an internal unit for your device. These are different items.

If a separate board is considered, ask for its actual condition, completeness and conditions of verification after installation. The component number in the historical manual is not a confirmation of its current availability. Restoration, configuration and final verification are entrusted to a qualified service.

How to confirm the recovery result

Check the sound path and other required station functions. For the declared sound loss, it is useful to check steady operation, not just a brief inclusion. The act must indicate the specific copy, the work performed and the result of the agreed test.

Temporary repetition of the adopted speech is separately considered in technical guide Replay RT5022. Here we are talking about the choice of hardware node and the amount of recovery; serviceability of the Replay function in the repair fund is not automatically assumed.

Card and documents

Supply and coordination

The RadarStation SAILOR RT-5022 card contains one copy for recovery, with the price in the product card. This is the station's repair fund. The serviceability, operational readiness and the remainder of the BaseBand or S-328.700 are not confirmed by this line. The volume of recovery and the achieved result are agreed separately.

Price and term - by quotation for the agreed composition. Specify the port or city, the required date, documents and method of acceptance. A mark in the catalog helps to select a position for the request; the actual balance and reserve are confirmed before the order.

Request a quote

Select a different theme for the technical guide