S.P. Radio SAILOR N420: 24/13.2 V regulator and power-on control
SAILOR N420 is a separate power supply regulator for DC equipment. Technical Manual S.P. factory Radio A/S is described as a linear sequential 24V DC → 13.2V DC. When ordering a replacement, not only voltages are important, but also regular control of the inclusion from the connected radio.
What parameters are given in the N420 manual
Section 1.1 specifies a working input of 21.6–31.2 V DC, an output of 13.2 V DC, and a maximum output current of 8 A. The designation “24/12 V” in the short catalogue name does not replace these values. Before agreeing on delivery, they are compared with the marking of a particular block and the requirements of the retained load.
N420 is considered as a DC circuit node. If the original task involves power supply from the AC network, battery charge or reserve the entire post, the required composition of the system is described separately. So the quotation on the regulator will not be mistaken for a ready-made solution of all power supply problems.
Linear circuit and heat removal
Section 1.2 refers to N420 as a linear regulator; much of the loss is dissipated in resistors. This feature is important when preserving the installation site and coordinating the load. The conditions of inspection and heat removal shall be in accordance with the specific configuration and applicable documentation.
For a used product, it is useful to request the condition of the housing and cooling surfaces, the full marking and the result of an agreed inspection. The appearance of the desired voltage without a load does not describe the behavior of the unit in all the required mode of operation.
Enabling from radio - part of the check
The manual specifies the control of the controller of the switch on the connected VHF station and a separate remote shut-down chain. Therefore, when replacing, you need to keep the prescribed control method, and not be limited to comparing the power input and output.
In the request, specify the model of the powered equipment and how the post is turned on now. The service checks the connections according to the documentation of this installation. This technical guide does not specify the patterning and does not suggest changing the lintel control circuit according to the general description.
What does the 24613G board revision mean?
The diagram in the factory manual is marked PCB rev. 24613G. This is a binding of a published drawing, not an audit confirmation of any warehouse. N420. If the block to be removed differs, the applicability of the documentation and the replacement is clarified before the order.
It is enough for the buyer to attach photos of the available marking and existing installation, specify the retained load and the desired date. The quotation fixes the configuration, condition, composition and verification of the proposed copy. The documented maximum current value does not replace the result of its verification under agreed conditions.
Card and documents
- S.P. Radio SAILOR N420 in the RadarStation catalog
- S.P. Radio A/S: Technical Manual for24V/12VRegulatorN420, §1.1–1.2 and PCB rev.24613G
- Text archive copy of the same factory Technical Manual N420
Supply and coordination
In the catalog lines N420 indicate the former in service products and the condition "under restoration"; price in the product card. The proposed copy, its condition, verification, actual reserve and completeness are agreed separately. Repeating the N420 designation in the catalog does not confirm different configurations or the total number of available products.