Japan Radio JRC NWZ-173: CMH-2227, CBF-38 and CCK-989 boards
To repair the monitor Japan Radio JRC NWZ-173 request "display board" is better to specify the factory number. Inside the documented configuration are separated interface, inverter, brightness control and other nodes. This helps to coordinate the delivery of the desired part or compare it with the replacement of the monitor assembly.
Request quotation: Japan Radio JRC NWZ-173/CMH-2227/CBF-38/CCK-989
What numbers do the JRC distinguish?
In Field Service Manual 7ZPRD0715 for JMA-5300Mk2 table 3-9 section 4.5 There are five electronic monitor positions. NWZ-173.
| Number. | Use |
|---|---|
| CMH-2227 | Interface board |
| CBF-38 | Inverter |
| CCK-989 | Brightness control |
| CML-771 | LCD panel |
| CBP-173A | Blower Circuit node |
In the internal scheme 7-26, these symbols are given with the prefix H-. Save the actual entry from the marking in its entirety: a short designation from the section header does not replace the part configuration check.
First identify the monitor version, then the board
In our catalog, the warehouse monitor is designated NWZ-173-DT. The service document describes NWZ-173 in a specific configuration of JMA-5300Mk2. Therefore, it is impossible to transfer the list of details to any monitor of the series by one coincidence of numbers. Before a separate order, the full type, serial number and applicable statement are agreed.
If the service specialist has already removed the faulty node, attach its number, revision and available photos of the connectors. If there is only a conclusion, save its wording in the application. It is not necessary to disassemble the working monitor just to fill out the letter.
What to compare in quotation
The interface board, inverter and LCD panel should go in different rows. Clarify if only the named element or a larger assembly with cables and mounting is supplied. To replace the entire monitor, separately list the retained connections and accessories.
The lack of image or uncomfortable brightness does not determine the article of purchase without diagnosis. Ask to fix which node is recognized as faulty and what confirmed the applicability of the proposed replacement. As a result of the repair, the image check and brightness adjustment are coordinated, and the configuration of the used monitor is documented.
Electronics and mechanical fastening
MPBC42446 stands are a separate issue of accommodation. It reveals. technical guide monitor and stand. In the request for an electronic node, specify whether the monitor is saved entirely and what part is needed. Separate stock of internal components due to the presence of the monitor is not expected.
Card and documents
- Japan Radio JRC NWZ-173 / CMH-2227 / CBF-38 / CCK-989 in the RadarStation catalog
- JRC: Field Service Manual 7ZPRD0715, June 2008, Edition 1 - archival copy; Table 3-9, §4.5.2-4.5.6 and Figure 7-26
Supply and coordination
The NWZ-173-DT monitor’s own RadarStation card lists the New · 1, price on request. This is the rest of the monitor in the collection, not individual boards. The manual describes NWZ-173; the applicability of the listed nodes to a particular NWZ-173-DT, separate availability and delivery kit require confirmation.
Price and term - by quotation for the agreed composition. Specify the port or city, the required date, documents and method of acceptance. A mark in the catalog helps to select a position for the request; the actual balance and reserve are confirmed before the order.
Request quotation: Japan Radio JRC NWZ-173/CMH-2227/CBF-38/CCK-989